Search results

Jump to navigation Jump to search
  • ...rge|#Field help text too large (too many lines or too long) to display, or text is over 1017 characters long. #A single line of the field help is longer than the ([[Session Cols]]-3) characters ...
    536 bytes (94 words) - 17:46, 28 June 2013
  • |Field help text not terminated properly |Field help text not terminated properly ...
    275 bytes (37 words) - 17:46, 28 June 2013
  • |Text exceeds field length |Text exceeds field length ...
    95 bytes (12 words) - 17:46, 28 June 2013
  • |Invalid field help text termination character |Invalid field help text termination character. ...
    206 bytes (28 words) - 17:46, 28 June 2013
  • |Invalid backward reference to help field |Invalid backward reference to help field. The "&field-number" parameter in a help string is invalid. ...
    408 bytes (65 words) - 17:46, 28 June 2013
  • == TEXT FIELD FORMAT== 10 (R)INPUT FIELDS “row, col, TEXT rows/cols[/capacity], leading-attr, …”: ...
    2 KB (356 words) - 17:06, 9 July 2018
  • TEXT ENTRY FIELD PROCESSING The string ( C/V/G ) field leading attribute ^ENTER_CRLF is supported as follows. ...
    1 KB (252 words) - 18:05, 25 September 2014
  • The default under Windows is to reverse each field as it is entered, and to position the cursor at the end of the data. This t ...ser's Windows specifications for selected text should apply to highlighted text. ...
    492 bytes (79 words) - 03:57, 6 December 2021
  • Q
    The letter "Q" as a [[screen attribute]] will create a hot text field. See [[Attribute (Screen)#Control Attributes|control attributes]]. ...
    191 bytes (24 words) - 16:06, 7 August 2013
  • ...fies the user level, window placement, and text that is to be displayed in field help windows. ...nfig.sys FIELDHELP specification. The border types which are available for field help windows are the same as the border types which are available for regul ...
    8 KB (1,224 words) - 15:22, 21 May 2016
  • The following syntax may be inserted where the "field- spec" parameter appears in the main diagram for full screen processing sta ...UMN, {<[[numeric form spec]]>|<[[string form spec]]>|<[[PIC]](<pic spec>}[<field length>] [.<fraction length>] [, <[[attributes]]>] [;...] ...
    3 KB (497 words) - 03:23, 20 January 2020
  • ...ecified as the field length. If field length is not specified, the default field length is the length of the string (including spaces); CC centers the value The following example will center the text on the second line of the screen: ...
    1 KB (218 words) - 20:12, 10 October 2013
  • ...ied as the field length. If the field length is not specified, the default field length is the length of the string (including spaces); CR right justifies t ...e, lines 1100 and 1200 will print text flush against the right edge of the field so that the two colons will both appear in column 20 of the screen: ...
    1 KB (198 words) - 15:30, 7 August 2013
  • For disambiguation purposes, see also the full screen processing section [[Field Help]]. ...dentifies the text attributes and border type that are to be used whenever field help windows are specified in INPUT FIELDS, RINPUT FIELDS, INPUT SELECT and ...
    3 KB (539 words) - 15:28, 8 April 2013
  • ...d. When this message is displayed, an error code also appears in the error field of the status line. ...occurs and the error code number first appears it is displayed in reverse text. As soon as Enter or an arrow key has been pressed, however, the display ch ...
    1,019 bytes (177 words) - 20:33, 16 July 2013
  • ...s. When this message is displayed, an error code also appears in the error field of the status line. ...occurs and the error code number first appears it is displayed in reverse text. As soon as Enter or an arrow key has been pressed, however, the display ch ...
    1 KB (180 words) - 19:39, 23 June 2014
  • ...PUT operations pertain only to the text field and respond just like a text field. If Enter is pressed while entering data, then an Enter action is taken. I Set the text default field value: (this second step is entirely optional and is often omitted) ...
    4 KB (654 words) - 01:45, 28 October 2014
  • ...next field after data entry to the last position in this field in multiple field processing. ...is specified for more than one field, the cursor is positioned in the last field of the array containing the C attribute. ...
    5 KB (871 words) - 15:27, 27 June 2019
  • ...that are applicable for a given statement are identified in the parameters text for that statement. See [[Format specifications]] for details. ...full screen processing statements (PRINT FIELDS, INPUT FIELDS, and RINPUT FIELD); they cannot be used in either type of FORM statement. ...
    548 bytes (94 words) - 17:03, 29 April 2014
  • Version [[4.1]]+ allows specific proportional or non-proportional fonts for text, labels and buttons SCREEN OPENDFLT FONT=, FONT.TEXT=, FONT.LABELS=, FONT.BUTTONS= ...
    3 KB (470 words) - 15:57, 16 July 2014
  • ...ark:} Pressing F7 causes Business Rules to mark the starting point of the text to be copied or moved. Business Rules highlights the starting position and ...the marked text into a scratch buffer. To help you confirm that the marked text has been copied, the message "x Bytes Saved" (where "x" represents the numb ...
    7 KB (1,212 words) - 19:28, 17 July 2013
  • CHR$(6) implies right justify the previous field for printed output. ...fy applies to the following text whereas CHR$(6) pertains to the preceding text. ...
    1 KB (223 words) - 18:53, 23 September 2014
  • ...ccupy using a fixed width font. When this happens, BR extends the control (text space) to the length of the data. If a label is subsequently displayed on t The new console extends graphical controls, such as buttons and text fields, by three pixels on each side. This means you should allow one blank ...
    5 KB (769 words) - 21:03, 3 July 2015
  • R99C999 (BR row & col) now appears in the text field of BR labels (BR Version 4.3 and higher). ...in Autoit as EditNN where NN is the INPUT FIELDS subscript (CURFLD) of the field. ...
    2 KB (301 words) - 18:25, 19 September 2014
  • ...es. This feature allows for a different "current" attribute for each input field. Thus if using INPUT SELECT to select many items from a list, the non-curre ...rray or the first error. If there are not enough attributes for each entry field, the first one will be used. For an example of this feature in action, ente ...
    10 KB (1,566 words) - 16:41, 22 September 2014
  • A new field attribute is defined that may be specified in ATTRIBUTE statements and in F OPTION 50 ! suppress Windows themes for text boxes only ...
    1 KB (186 words) - 19:33, 22 September 2014
  • ...] system functions to be set. RInput Select additionally allows the use of field help windows for any or all of the defined fields. ...e same column as the cursor, the up or down arrow will stay at the current field. ...
    11 KB (1,785 words) - 00:10, 6 May 2014
  • ...ly in full screen processing statements, but they may also be used in help text files (see [[Help Facility]] for more information about this usage). We beg ...ignored because they are irrelevant for PRINT FIELDS. Line 2040 displays a field with red letters on a blue background: ...
    7 KB (1,042 words) - 13:53, 27 November 2014
  • CurFld ([<New_current_field>] [,<New_current_row>]) ! if the new current field is a ListView CurFld ([<New_current_field>] [,<New_current_cell>])! if the new current field is a Grid ...
    9 KB (1,446 words) - 15:22, 19 May 2019
  • INSERT [ON|OFF] NON_PERSISTENT - resets to specified setting upon field exit == New Text Entry Field Attribute == ...
    7 KB (1,057 words) - 18:38, 9 December 2016
  • ...tive position of the control within the Fields operation. However, for hot field identification it is necessary to use Fkey values to identify the respectiv NXTFLD([<New_current_field>] [,<New_current_row>]) ! if the new current field is a ListView ...
    9 KB (1,383 words) - 18:21, 23 September 2014
  • ...NAL, EXTERNAL, or DISPLAY files. Display files can be read in any standard text editor, while the other two are BR specific formats. They can also not be o ...o finish. Keyed means that the record will be according to a specified KEY field. ...
    1 KB (227 words) - 18:36, 10 September 2014
  • ...the number of the line where the error occurred appears in the line number field. ...s, the number of the line to be executed next is listed in the line number field of the status line. It is possible to execute most Business Rules instructi ...
    6 KB (1,069 words) - 02:14, 16 July 2013
  • ...D system functions to be set. Additionally, INPUT SELECT allows the use of field help windows for any or all of the defined fields. ...has an associated field help window which is automatically displayed upon field entry when the BRConfig.sys USERLEVEL specification is set to anything but ...
    13 KB (1,992 words) - 15:21, 5 May 2014
  • ...the space it must occupy, including a character or attribute from another field. ;I/O windows and field help windows are also affected by terminals that use a space for the attrib ...
    4 KB (609 words) - 15:39, 16 July 2013
  • ...tributes. In addition, the Input Fields statement uses the capabilities of field help windows to set up help messages for any or all of the fields it define See (4.3) [[Text]] format. ...
    15 KB (2,297 words) - 04:01, 31 July 2022
  • ...simply a text document written in HTML and CSS. Your web browser reads the text document, and follows the instructions on what to display and how to displa ...over both of them, the main difference is where the majority of your html text is stored. ...
    8 KB (1,362 words) - 21:09, 15 July 2013
  • ...exists, with a new index file for the master file MASTER.FIL. The key is a field that starts at position 10 and consists of 5 characters: .... The second key starts at position 10 and has 2 characters, and the third field starts at position 20 and has 2 characters: ...
    9 KB (1,571 words) - 15:34, 4 March 2021
  • A new field attribute is defined that may be specified in ATTRIBUTE statements and in F OPTION 50 ! suppress Windows themes for text boxes only ...
    8 KB (1,211 words) - 18:58, 17 July 2013
  • ...given initial focus by INPUT processing, such as with CURFLD or the first field of a FIELDS operation. Either P or PICTURE may be specified as a FIELDS field type. Picture was added for readability. ...
    7 KB (1,041 words) - 17:49, 23 July 2013
  • |width="10%"|'''MAT MESSAGE$'''||email text in the form of a matrix ===FNEMAILFILE - inserts a text file into an email for email monitor=== ...
    6 KB (852 words) - 17:09, 11 July 2013
  • help text (tool tips) can also be used on a button. ...'s syntax is the same as the [[Print Fields]] syntax below. However, the [[Field Spec]] parameter must also include a '''B''' attribute followed by the desi ...
    8 KB (1,187 words) - 15:16, 21 May 2016
  • ...R to return old [[FKey]] value when someone uses the right arrow to exit a field (returns FKey 104 (down arrow) ! E, L or X field attributes. Without this Option, the mouse wheel returns Fkey results of 12 ...
    4 KB (561 words) - 14:43, 4 November 2019
  • some printers require in order to print ordinary text. This pertains to versions [[4.0]] and later: Occasionally it is necessary to extend a field to the length it would be if it ...
    7 KB (1,006 words) - 16:24, 13 July 2013
  • ::*FNSEQ - Return the next sequence for a key field ::*FNTYPE - Move the contents of one text file into another open file ...
    10 KB (1,616 words) - 15:43, 27 November 2014
  • ...]] statements to format input or output. FORM controls the size, location, field length and format of input or output. ...form spec]]>< field length>[.<fraction length>]}|<[[string form spec]]>[ <field length>]|<[[floating point form spec]]>}[,...] ...
    12 KB (1,914 words) - 14:30, 5 May 2014
  • ...un it alone. The sort control file can also be created as a PROC file in a text editor. See the example near the top of this page. ...e replaced with zeroes for sorting purposes, provided the remainder of the field contains only numeric data. ...
    2 KB (354 words) - 19:19, 7 August 2013
  • The enabling of the help facility causes Business Rules to access a text file, from which it displays a help screen. The particular screen that Busi ...ng Statements]] and the [[Field Help]] sections for more information about field help windows. ...
    39 KB (6,625 words) - 17:25, 13 July 2013
  • |width="10%"|'''BUTTON_TEXT$'''||Text to display on button. Must be less than 10 characters ===FNDIALOG$*40 - Display dialog box and return selected text=== ...
    25 KB (3,874 words) - 17:09, 11 July 2013
  • ...|With versions [[4.14]]+, BR returns: [[FKEY]] value of 116 when exiting a field with right arrow. |'''40'''||Show hot text as buttons by default. Normally hot text does not appear as a button unless the fkey value is preceded with a B. Thi ...
    11 KB (1,724 words) - 16:50, 25 July 2020
  • |width="10%"|'''Font types'''||FONT= FONT.TEXT= FONT.LABELS= FONT.BUTTONS= ...ute spec is active, the following INPUT FIELDS will display a 10-character field in underline (on a monochrome monitor) or in white letters on a blue backgr ...
    8 KB (1,173 words) - 19:53, 11 October 2022
  • ...ude multiple sort positions and types in the start position, field length, field format and ascending or decending as in "11,5,C,A" or "11,5,C,A,21,5,PD D". ===FNSEQ - Return the next sequence for a key field=== ...
    15 KB (2,470 words) - 17:09, 11 July 2013
  • ...ude multiple sort positions and types in the start position, field length, field format and ascending or descending as in "11,5,C,A" or "11,5,C,A,21,5,PD D" ===FNSEQ - Return the next sequence for a key field=== ...
    15 KB (2,470 words) - 17:09, 11 July 2013
  • ...row, column, conversion, and attribute specifications together to create a field definition. *Understand the uses of arrays in multiple field processing. ...
    45 KB (7,493 words) - 17:17, 16 August 2013
  • #First click that sets focus on a control now works like it does when the field is entered via the arrow keys. #If a conversion error occurred on a field with a help window open BR would become unstable. ...
    21 KB (3,152 words) - 19:14, 16 September 2013
  • This text is origionally from NWP.DOC from [ftp://ftp.brulescorp.com ftp.brulescorp.c ...er setting the pitch, BR ignores the HMI until the last character of each ‘field’ has been printed, and then positions the cursor as if HMI had been honored ...
    15 KB (2,382 words) - 16:11, 9 December 2016
  • ...back or change it as well. Data files can be created through BR itself, a text editor, or any third party program editor. ...on that a data file can hold. Data files can hold messages, paragraphs of text, or just about anything else you would want them to hold. ...
    18 KB (3,193 words) - 17:18, 16 August 2013
  • OPTION 50 Suppress theme usage for text controls. This enables the Windows classical look under XP. ...anywhere in a non-current active input field will process it as though the field were entered via the arrow keys. ...
    9 KB (1,375 words) - 16:24, 13 July 2013
  • * Attributes to be used for the text area of the window This will input the first two fields on window #121 and the third field on window #124. The ‘#window-number,’ prefix may appear in any row or col ...
    14 KB (2,180 words) - 15:04, 6 May 2017
  • The '''Open (OPE) Display''' [[statement]] activates a text file for input/output or opens a printer for output. ...es (the other two file types are internal and external). Display files are text files that contain [[ASCII]] characters as data. It is often useful to thin ...
    17 KB (2,787 words) - 15:00, 27 January 2017
  • Sort control files can be created in a text editor as a procedure file, or as an internal file using WRITE. The simples ...t file will not be in sorted order if SHR is specified and a record's sort field is modified by another workstation during the sort. (See "[[share specs]]" ...
    28 KB (4,683 words) - 19:58, 9 June 2023
  • ...cify a trailing "Y" character to indicate that the first two digits of the field are BASEYEAR dependent. For example: Indicates that a date field begins in position 23 with a two digit year that is [[BASEYEAR]] dependent. ...
    22 KB (3,410 words) - 19:20, 17 July 2013
  • Prints a message on the message line and optionally center the text. Check to see if a CMDKEY or FKEY was pressed and produce an error for field C ...
    7 KB (1,011 words) - 17:09, 11 July 2013
  • ====Field Length==== ...an integer value, which identifies the number of columns in the specified field. This parameter is required as a part of any numeric format specification e ...
    18 KB (2,724 words) - 14:33, 5 May 2014
  • 2. Comparing two loans. Due to the length of the program, it’s presented as a text file. 00265 PRINT ! serves to drop the cursor down one line to separate text ...
    15 KB (1,877 words) - 16:14, 21 December 2019
  • ...may be used to specify starting cursor positions, automatic entry of data, field protection and more. ====Multiple Field Processing==== ...
    72 KB (11,525 words) - 15:26, 11 July 2020
  • ...routines are in a separate DLL that is automatically invoked based on the field's class type when a property value is sent or received by BR via a properti ...endar, an "Add Event" button, combo boxes for hour and minute selection, a text box for entering an event description, and a timer which will check every ...
    12 KB (1,843 words) - 17:11, 25 September 2014
  • ...ded into rows and columns.  A row is the horizontal space that one line of text takes up on the screen.  A column is the vertical space that a single chara ...basically refers to the space allotted to a piece of information, usually text. ...
    35 KB (5,608 words) - 17:11, 25 April 2020
  • Using the Q attribute to display a combo box character caused the field in question to have data superimposed over itself in a smaller raised font. The Combo Box Graphic was dissappearing when the cursor ATTR field was also specified, or when the window was minimized and restored. ...
    21 KB (3,294 words) - 16:24, 13 July 2013
  • ...images to be applied to the bitmap workspace. Many effects are possible. Text may be greyed or striped like a candy cane. ...osition to the top left of the page, or you can modify the commands in the text file to reset the position to any specific location on the page you want. Y ...
    36 KB (5,870 words) - 11:18, 21 September 2019
  • *Define keyed file processing, key field and key file. *Use keyed processing to read a file as if sorted by the key field. ...
    52 KB (8,954 words) - 17:21, 16 August 2013
  • ...Function that is tied to a data file (through fileIO) and has no editable text controls on it, and has a Listview on it somewhere. ...een function that is tied to a data file (through fileIO) and has editable text controls on it, and no Listivew control on it anywhere. An Add/Edit screen ...
    156 KB (26,665 words) - 21:15, 31 July 2022
  • ...ly either the value assigned to a parameter or the content of an HTML FORM field. When supporting iPad or smart phone applications a value can be a complete "text": { ...
    21 KB (3,149 words) - 14:57, 22 May 2016
  • The trick is to define your file layouts in an ASCII text file layout file that I will tell you about in a minute. The FileIO Library The file IO library parses a formatted text file layout and uses this information to structure the opening and initiali ...
    127 KB (21,265 words) - 15:12, 9 September 2021
  • ...activity. It lists all the fields in a single record and tells where each field is found within that record. Throughout the remainder of the file processi |Field ...
    65 KB (11,096 words) - 19:43, 11 April 2018
  • CHR$(6) is a field separator that displays as a space but causes the immediately preceding dat BRERR$(0875) returns “unrecognized data after field specification” ...
    79 KB (11,677 words) - 17:15, 25 July 2020
  • ...the subfolders are identified by the symbol <DIR> in the second column of text. ...anything that does not start with a backslash; the system cannot find any field or folder with the resulting name D:\Programs.  It is not in the root folde ...
    48 KB (8,436 words) - 17:16, 16 August 2013