Search results

Jump to navigation Jump to search
View (previous 50 | ) (20 | 50 | 100 | 250 | 500)
  • ...rge|#Field help text too large (too many lines or too long) to display, or text is over 1017 characters long. #A single line of the field help is longer than the ([[Session Cols]]-3) characters ...
    536 bytes (94 words) - 17:46, 28 June 2013
  • |Field help text not terminated properly |Field help text not terminated properly ...
    275 bytes (37 words) - 17:46, 28 June 2013
  • |Text exceeds field length |Text exceeds field length ...
    95 bytes (12 words) - 17:46, 28 June 2013
  • |Invalid field help text termination character |Invalid field help text termination character. ...
    206 bytes (28 words) - 17:46, 28 June 2013
  • |Invalid backward reference to help field |Invalid backward reference to help field. The "&field-number" parameter in a help string is invalid. ...
    408 bytes (65 words) - 17:46, 28 June 2013
  • == TEXT FIELD FORMAT== 10 (R)INPUT FIELDS “row, col, TEXT rows/cols[/capacity], leading-attr, …”: ...
    2 KB (356 words) - 17:06, 9 July 2018
  • TEXT ENTRY FIELD PROCESSING The string ( C/V/G ) field leading attribute ^ENTER_CRLF is supported as follows. ...
    1 KB (252 words) - 18:05, 25 September 2014
  • The default under Windows is to reverse each field as it is entered, and to position the cursor at the end of the data. This t ...ser's Windows specifications for selected text should apply to highlighted text. ...
    492 bytes (79 words) - 03:57, 6 December 2021
  • Q
    The letter "Q" as a [[screen attribute]] will create a hot text field. See [[Attribute (Screen)#Control Attributes|control attributes]]. ...
    191 bytes (24 words) - 16:06, 7 August 2013
  • ...fies the user level, window placement, and text that is to be displayed in field help windows. ...nfig.sys FIELDHELP specification. The border types which are available for field help windows are the same as the border types which are available for regul ...
    8 KB (1,224 words) - 15:22, 21 May 2016
  • The following syntax may be inserted where the "field- spec" parameter appears in the main diagram for full screen processing sta ...UMN, {<[[numeric form spec]]>|<[[string form spec]]>|<[[PIC]](<pic spec>}[<field length>] [.<fraction length>] [, <[[attributes]]>] [;...] ...
    3 KB (497 words) - 03:23, 20 January 2020
  • ...ecified as the field length. If field length is not specified, the default field length is the length of the string (including spaces); CC centers the value The following example will center the text on the second line of the screen: ...
    1 KB (218 words) - 20:12, 10 October 2013
  • ...ied as the field length. If the field length is not specified, the default field length is the length of the string (including spaces); CR right justifies t ...e, lines 1100 and 1200 will print text flush against the right edge of the field so that the two colons will both appear in column 20 of the screen: ...
    1 KB (198 words) - 15:30, 7 August 2013
  • For disambiguation purposes, see also the full screen processing section [[Field Help]]. ...dentifies the text attributes and border type that are to be used whenever field help windows are specified in INPUT FIELDS, RINPUT FIELDS, INPUT SELECT and ...
    3 KB (539 words) - 15:28, 8 April 2013
  • ...d. When this message is displayed, an error code also appears in the error field of the status line. ...occurs and the error code number first appears it is displayed in reverse text. As soon as Enter or an arrow key has been pressed, however, the display ch ...
    1,019 bytes (177 words) - 20:33, 16 July 2013
  • ...s. When this message is displayed, an error code also appears in the error field of the status line. ...occurs and the error code number first appears it is displayed in reverse text. As soon as Enter or an arrow key has been pressed, however, the display ch ...
    1 KB (180 words) - 19:39, 23 June 2014
  • ...PUT operations pertain only to the text field and respond just like a text field. If Enter is pressed while entering data, then an Enter action is taken. I Set the text default field value: (this second step is entirely optional and is often omitted) ...
    4 KB (654 words) - 01:45, 28 October 2014
  • ...next field after data entry to the last position in this field in multiple field processing. ...is specified for more than one field, the cursor is positioned in the last field of the array containing the C attribute. ...
    5 KB (871 words) - 15:27, 27 June 2019
  • ...that are applicable for a given statement are identified in the parameters text for that statement. See [[Format specifications]] for details. ...full screen processing statements (PRINT FIELDS, INPUT FIELDS, and RINPUT FIELD); they cannot be used in either type of FORM statement. ...
    548 bytes (94 words) - 17:03, 29 April 2014
  • Version [[4.1]]+ allows specific proportional or non-proportional fonts for text, labels and buttons SCREEN OPENDFLT FONT=, FONT.TEXT=, FONT.LABELS=, FONT.BUTTONS= ...
    3 KB (470 words) - 15:57, 16 July 2014
  • ...ark:} Pressing F7 causes Business Rules to mark the starting point of the text to be copied or moved. Business Rules highlights the starting position and ...the marked text into a scratch buffer. To help you confirm that the marked text has been copied, the message "x Bytes Saved" (where "x" represents the numb ...
    7 KB (1,212 words) - 19:28, 17 July 2013
  • CHR$(6) implies right justify the previous field for printed output. ...fy applies to the following text whereas CHR$(6) pertains to the preceding text. ...
    1 KB (223 words) - 18:53, 23 September 2014
  • ...ccupy using a fixed width font. When this happens, BR extends the control (text space) to the length of the data. If a label is subsequently displayed on t The new console extends graphical controls, such as buttons and text fields, by three pixels on each side. This means you should allow one blank ...
    5 KB (769 words) - 21:03, 3 July 2015
  • R99C999 (BR row & col) now appears in the text field of BR labels (BR Version 4.3 and higher). ...in Autoit as EditNN where NN is the INPUT FIELDS subscript (CURFLD) of the field. ...
    2 KB (301 words) - 18:25, 19 September 2014
  • ...es. This feature allows for a different "current" attribute for each input field. Thus if using INPUT SELECT to select many items from a list, the non-curre ...rray or the first error. If there are not enough attributes for each entry field, the first one will be used. For an example of this feature in action, ente ...
    10 KB (1,566 words) - 16:41, 22 September 2014
  • A new field attribute is defined that may be specified in ATTRIBUTE statements and in F OPTION 50 ! suppress Windows themes for text boxes only ...
    1 KB (186 words) - 19:33, 22 September 2014
  • ...] system functions to be set. RInput Select additionally allows the use of field help windows for any or all of the defined fields. ...e same column as the cursor, the up or down arrow will stay at the current field. ...
    11 KB (1,785 words) - 00:10, 6 May 2014
  • ...ly in full screen processing statements, but they may also be used in help text files (see [[Help Facility]] for more information about this usage). We beg ...ignored because they are irrelevant for PRINT FIELDS. Line 2040 displays a field with red letters on a blue background: ...
    7 KB (1,042 words) - 13:53, 27 November 2014
  • CurFld ([<New_current_field>] [,<New_current_row>]) ! if the new current field is a ListView CurFld ([<New_current_field>] [,<New_current_cell>])! if the new current field is a Grid ...
    9 KB (1,446 words) - 15:22, 19 May 2019
  • INSERT [ON|OFF] NON_PERSISTENT - resets to specified setting upon field exit == New Text Entry Field Attribute == ...
    7 KB (1,057 words) - 18:38, 9 December 2016
  • ...tive position of the control within the Fields operation. However, for hot field identification it is necessary to use Fkey values to identify the respectiv NXTFLD([<New_current_field>] [,<New_current_row>]) ! if the new current field is a ListView ...
    9 KB (1,383 words) - 18:21, 23 September 2014
  • ...NAL, EXTERNAL, or DISPLAY files. Display files can be read in any standard text editor, while the other two are BR specific formats. They can also not be o ...o finish. Keyed means that the record will be according to a specified KEY field. ...
    1 KB (227 words) - 18:36, 10 September 2014
  • ...the number of the line where the error occurred appears in the line number field. ...s, the number of the line to be executed next is listed in the line number field of the status line. It is possible to execute most Business Rules instructi ...
    6 KB (1,069 words) - 02:14, 16 July 2013
  • ...D system functions to be set. Additionally, INPUT SELECT allows the use of field help windows for any or all of the defined fields. ...has an associated field help window which is automatically displayed upon field entry when the BRConfig.sys USERLEVEL specification is set to anything but ...
    13 KB (1,992 words) - 15:21, 5 May 2014
  • ...the space it must occupy, including a character or attribute from another field. ;I/O windows and field help windows are also affected by terminals that use a space for the attrib ...
    4 KB (609 words) - 15:39, 16 July 2013
  • ...tributes. In addition, the Input Fields statement uses the capabilities of field help windows to set up help messages for any or all of the fields it define See (4.3) [[Text]] format. ...
    15 KB (2,297 words) - 04:01, 31 July 2022
  • ...simply a text document written in HTML and CSS. Your web browser reads the text document, and follows the instructions on what to display and how to displa ...over both of them, the main difference is where the majority of your html text is stored. ...
    8 KB (1,362 words) - 21:09, 15 July 2013
  • ...exists, with a new index file for the master file MASTER.FIL. The key is a field that starts at position 10 and consists of 5 characters: .... The second key starts at position 10 and has 2 characters, and the third field starts at position 20 and has 2 characters: ...
    9 KB (1,571 words) - 15:34, 4 March 2021
  • A new field attribute is defined that may be specified in ATTRIBUTE statements and in F OPTION 50 ! suppress Windows themes for text boxes only ...
    8 KB (1,211 words) - 18:58, 17 July 2013
  • ...given initial focus by INPUT processing, such as with CURFLD or the first field of a FIELDS operation. Either P or PICTURE may be specified as a FIELDS field type. Picture was added for readability. ...
    7 KB (1,041 words) - 17:49, 23 July 2013
  • |width="10%"|'''MAT MESSAGE$'''||email text in the form of a matrix ===FNEMAILFILE - inserts a text file into an email for email monitor=== ...
    6 KB (852 words) - 17:09, 11 July 2013
  • help text (tool tips) can also be used on a button. ...'s syntax is the same as the [[Print Fields]] syntax below. However, the [[Field Spec]] parameter must also include a '''B''' attribute followed by the desi ...
    8 KB (1,187 words) - 15:16, 21 May 2016
  • ...R to return old [[FKey]] value when someone uses the right arrow to exit a field (returns FKey 104 (down arrow) ! E, L or X field attributes. Without this Option, the mouse wheel returns Fkey results of 12 ...
    4 KB (561 words) - 14:43, 4 November 2019
  • some printers require in order to print ordinary text. This pertains to versions [[4.0]] and later: Occasionally it is necessary to extend a field to the length it would be if it ...
    7 KB (1,006 words) - 16:24, 13 July 2013
  • ::*FNSEQ - Return the next sequence for a key field ::*FNTYPE - Move the contents of one text file into another open file ...
    10 KB (1,616 words) - 15:43, 27 November 2014
  • ...]] statements to format input or output. FORM controls the size, location, field length and format of input or output. ...form spec]]>< field length>[.<fraction length>]}|<[[string form spec]]>[ <field length>]|<[[floating point form spec]]>}[,...] ...
    12 KB (1,914 words) - 14:30, 5 May 2014
  • ...un it alone. The sort control file can also be created as a PROC file in a text editor. See the example near the top of this page. ...e replaced with zeroes for sorting purposes, provided the remainder of the field contains only numeric data. ...
    2 KB (354 words) - 19:19, 7 August 2013
  • The enabling of the help facility causes Business Rules to access a text file, from which it displays a help screen. The particular screen that Busi ...ng Statements]] and the [[Field Help]] sections for more information about field help windows. ...
    39 KB (6,625 words) - 17:25, 13 July 2013
  • |width="10%"|'''BUTTON_TEXT$'''||Text to display on button. Must be less than 10 characters ===FNDIALOG$*40 - Display dialog box and return selected text=== ...
    25 KB (3,874 words) - 17:09, 11 July 2013
  • ...|With versions [[4.14]]+, BR returns: [[FKEY]] value of 116 when exiting a field with right arrow. |'''40'''||Show hot text as buttons by default. Normally hot text does not appear as a button unless the fkey value is preceded with a B. Thi ...
    11 KB (1,724 words) - 16:50, 25 July 2020
View (previous 50 | ) (20 | 50 | 100 | 250 | 500)