Search results

Jump to navigation Jump to search
View ( | next 100) (20 | 50 | 100 | 250 | 500)
  • ...egory:Release 3.9|3.9]]. The statement must be placed in the configuration file to be effective. TYPE or LIST >LPT1: was failing. ...
    21 KB (3,294 words) - 16:24, 13 July 2013
  • The "OPEN communications" statement matches a file number in a program with a serial port used for communications. See the [[O ...ns file allows INPUT, LINPUT and PRINT statements to be used with the same file number. OUTIN is always necessary for proper line initialization to be sure ...
    9 KB (1,445 words) - 19:58, 13 July 2013
  • ...r barcodes. Barcodes can be used anywhere the software user is required to type in information. They can be used for both numbers and letters. Scanning a b ! create data file to tell program that font is already installed ...
    4 KB (581 words) - 23:12, 19 May 2014
  • Field Type & Length Assumed Data Format When using the [[FMT]] data type in [[INPUT FIELDS]] the tab key and back arrow generated a GPF. ...
    22 KB (3,410 words) - 19:20, 17 July 2013
  • The "#wind-num" parameter represents the file number of a window which has already been opened by an OPEN window statemen ...fies the following for each input field: row number; column number; format type, length and fraction length (if required) of the data to be input; and the ...
    7 KB (1,065 words) - 17:09, 5 May 2014
  • * Understand file structures and DIR listing. ====BR instructions -id -file -ref==== ...
    48 KB (8,436 words) - 17:16, 16 August 2013
  • Either P or PICTURE may be specified as a FIELDS field type. Picture was added for readability. ...identified in [[BRConfig.sys]] is accessed in lieu of an ordinary BR data file. ...
    7 KB (1,041 words) - 17:49, 23 July 2013
  • ...vironment changes your application need not change. Only the configuration file needs to change. ...omatically accesses at [[BR32.exe]] start-up. You can create and edit this file with any text editor. The line length is limited to 800 characters. See als ...
    12 KB (1,677 words) - 06:04, 6 December 2021
  • When REWRITING REC=, or just REWRITE after a READ REC=, to a file with indexes open, the indexes will be maintained. "|CTRL+|c|CTRL-|". This say that you want depress the "CTRL" key, type ...
    23 KB (3,634 words) - 16:29, 13 July 2013
  • ===Keyed File Processing=== *Define keyed file processing, key field and key file. ...
    52 KB (8,954 words) - 17:21, 16 August 2013
  • Either P or PICTURE may be specified as a FIELDS field type. Picture was added for readability. ...identified in [[BRConfig.sys]] is accessed in lieu of an ordinary BR data file. ...
    8 KB (1,211 words) - 18:58, 17 July 2013
  • ...iles appear and disappear at inappropriate times. Certain records within a file vanish. In short, operators can do just about anything. ...the statement causing the most recent error. -- Also file (filenum) gives file status. <br> ...
    31 KB (5,144 words) - 01:19, 16 July 2013
  • ....01 and .99. When RD is set to 6, it would take 1930 computations of this type to cause a rounding error. With an RD of 5, it would take more than 10,000 ...command can be used during program execution to override the BRConfig.sys file's RD specification. ...
    7 KB (1,086 words) - 02:59, 21 January 2020
  • ...d of being leading field attributes, is a secondary keyword indicating the type (CNT/SUB/CELL/ROWCNT/ROWSUB/ROW) of output or input operation to be perform ...hanged in a manner that enables selective data retrieval and corresponding file updating. ...
    41 KB (6,434 words) - 05:25, 5 February 2024
  • *Must specify WIN:/.... as the device type. This can be done with SUBSTITUTE statements and it overrides SPOOLCMD. Windows allows for independent specification of true type font height versus width. Under NWP the font height, width of a space chara ...
    15 KB (2,382 words) - 16:11, 9 December 2016
  • #) Copy your personal [[brserial.dat]] file into this directory (C:\Lexi). #) Select Tools / Configure User Tools / Import Tools. Select the "Lexi.mut" file that came in Lexi.zip. ...
    19 KB (2,904 words) - 12:41, 26 May 2016
  • Now that you’ve had an introduction to the world of file processing, we’re going to dive right into the use of internal files. When *Create a new internal file using the OPEN statement. ...
    65 KB (11,096 words) - 19:43, 11 April 2018
  • * Border type and attributes ...ion or integer that equals a value from 1 to 999, inclusive. No other open file or open window may use the same value. Open windows do not count against th ...
    14 KB (2,180 words) - 15:04, 6 May 2017
  • ...s long as they have been defined in CONFIG commands or in the BRConfig.sys file. If a subattribute is used but not defined, Business Rules will use the N d |width="10%"|'''Information'''||This type of window is also called a dialog box. ...
    8 KB (1,173 words) - 19:53, 11 October 2022
  • ...fonts. This function can be called from FNDLG that uses an unformatted BR file to supply text and button labels. Both functions have been updated to util ===FNDLG - Display a dialog box from data in a file=== ...
    25 KB (3,874 words) - 17:09, 11 July 2013
  • [[file:Helpstring.png|800px]] ...o lowercase). See the CL, CU, GL, GU, VL and VU format specifications in [[File I/O]] for more information. ...
    15 KB (2,297 words) - 04:01, 31 July 2022
  • LIST will list all occurrences of a single string when you type the string in quotation marks.  Since quotation marks signify a literal str 5. Type in the following commands while CHECKBAL is loaded and see what happens: <b ...
    30 KB (4,957 words) - 17:20, 21 December 2019
  • ...ains the indexed order of array N$, similar to the way an address-out sort file contains pointers to the original data. Lines 400 to 600 print the names in ...cribed with the [[DIM]] statement, with the important distinction that any type of numeric expression may be used -not just integer constants. ...
    12 KB (1,724 words) - 17:23, 23 May 2017
  • [[file:if.png|800px]] 00020 PRINT "Enter employee type" ...
    7 KB (915 words) - 14:41, 5 May 2014
  • ...remember that a field is the amount of space, either on the screen or in a file, which is reserved for a variable or constant.) ...e syntax gives information about the screen location (row and column), the type and length, special display or control instructions, and foreground and bac ...
    45 KB (7,493 words) - 17:17, 16 August 2013
  • ...it is available, but require no code changes when they are moved from one type of monitor to another. However, in newer versions of BR, the majority of mo ...
    7 KB (1,042 words) - 13:53, 27 November 2014
  • So far you have learned about the type of loop that you can create with GOTO statements, and you have experienced ...nd with a NEXT statement.  The following section of code shows an example. Type this example into Business Rules! and RUN it: ...
    26 KB (4,229 words) - 17:34, 25 April 2020
  • ...ey can change variable values outside the functions passed values, perform file I/O, and call themselves (recursively). Beyond the syntax of the DEF statem [[file:def.png|800px]] ...
    12 KB (1,964 words) - 15:21, 29 April 2014
  • ...nochrome or color attributes of a RINPUT FIELDS statement according to the type of monitor being used. ...oes for INPUT. Buffering may be turned on or off with the [[BRConfig.sys]] file [[TYPEAHEAD]] specification. ...
    10 KB (1,566 words) - 16:41, 22 September 2014
  • Type regclean with no parameters to see the instructions. Try typing “regclean – You may also run the included batch file fix.cmd batch file to unregister and reregister the product if you hare having trouble. ...
    30 KB (4,832 words) - 22:42, 15 October 2013
  • 3. Which type(s) of printing allow you to choose the number of digits which will be print ...n to another file or to a printer (you will learn more about printing to a file when you study the OPEN statement). ...
    35 KB (5,608 words) - 17:11, 25 April 2020
  • ...s and control is returned to the program while the 'current' control is of type [[LIST]] or [[GRID]], CURROW and CURCOL are set to the current cell row and ...s typically happens when executing a command such as COPY, or performing a file IO operation. The actual error code can be found in the new system variable ...
    7 KB (1,006 words) - 16:24, 13 July 2013
  • ...s.\nIf there is an apartment or suite number, \n type # and the number;2A<;Type in the full city name. \n Use the two-letter state code\n and the 9-digit z ...ss.\nIf there is an apartment or suite number,\ntype # and the number;2A<; Type in the full city name.\nUse the two-letter state code \n and the 9-digit zi ...
    72 KB (11,525 words) - 15:26, 11 July 2020
  • ===ON error-type IGNORE=== ON error-type IGNORE now ignores the error instead of going to an Ignore label. This is e ...
    79 KB (11,677 words) - 17:15, 25 July 2020
  • ...d. See the separate descriptions below for specific information about each type of library linkage. ...ve changes'' made to a running library program is to list the library to a file and reload it from source later on. Because of this, it can be desirable to ...
    30 KB (4,627 words) - 19:14, 17 April 2023
  • ...te of over 600 programs, more than one third of them referenced the commun file. With 223 programs to modify, the task was given up as hopeless and tabled ...ngle program needs to be changed in order to continue working with the new file layout. In fact, I don’t even have to update my customer’s data files, as t ...
    127 KB (21,265 words) - 15:12, 9 September 2021
  • Type [[STATUS]] ENV for other values. [[NWP]] support has been added for media type selection and printer tray strings. See NWP.TXT for details. ...
    21 KB (3,152 words) - 19:14, 16 September 2013
  • * Must specify WIN:/.... as the device type. ( This can be done with [[SUBSTITUTE]] statements. ) (see the HP PCL.PDF file for examples of fill chars) ...
    36 KB (5,870 words) - 11:18, 21 September 2019
  • ...ring two loans. Due to the length of the program, it’s presented as a text file. 00080 data "Check Number", "Amount", "Type of Transaction", "Date Written (ddmmyy)", "Date Cleared(ddmmyy)","Payee","A ...
    15 KB (1,877 words) - 16:14, 21 December 2019
  • ...time, and we wanted to share it with you. For example, a fully functional File Maintenance program can now be created in half an hour. A zoom function or ...ou have a complete FM program in two screens, for maintaining the customer file. But wait, what if you need a "Customer Selection" listview in your other p ...
    156 KB (26,665 words) - 21:15, 31 July 2022
View ( | next 100) (20 | 50 | 100 | 250 | 500)